The NI-Motion version is 7. used. 00 +$12. Send documents to the printer connected to your host computer or to the printer connected to the computer you are. 00 shippingSolved: I install NI PCI-7344. Hi, I am running a motor using the PCI 7344 motion control board and a MID-7654 servo with encoder feedback. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. WindowsXP system put it as unknown PXI-4200 board. The onboard CPU uses an embedded real-time OS. the drive feeds back a simulated. 1 were installed. . it is going to be sqaure wave signal . Since, I'm waiting in a loop for the Move Complete bit, the program (VB 6. Not all NI Motion controllers can control a step motor, but the following can: PCI-7332, PXI-7332, PCI-7334, PXI-7334, PCI-7342, PXI-7342, PCI-7344, PXI-7344, PCI-7352, PXI-7352, PCI-7354, PXI-7354, PCI-7356, PXI-7356, PCI-7358, PXI-7358, and PCI-7390. 25 ms to 1. (67 pages) Controller National Instruments 7932 Manual. This motion controller can control upto 4 servo motors and can give 2 PWM signal. 6 and LVRT 8. Ca hai ho tr ay u viec lap trnh ieu khien chuyen ong cho phep ieu khien toi a 4 truc ong thi va oc lap. I am using axis 3 with encoder 1 as the primary feedback, and as the control output. I initialise it using NI MAX (version 2. Is it possible to use the PCI-7344 board. umi-7764/7774をステッピングモーターメーカーのモータードライバに接続して使おうとしています。モータードライバはフォトカプラ入力になっています。どのように接続したらいいですか?From MAX, select your PCI-7344 under NI Motion Devices. I've been using NI, PCI-7344 motion controller. This version of "FlexMotion4. Right now, the +5V pins connected through an amplifier board to the "Host +5V" pin#59 in Motion I/O Connector of PCI-7344 board. As LabVIEW is widely used to control devices through standardized communication interfaces like RS232 or GPIB, there is a chance, that the. Is there any way to change the velocity while still col. (21 pages) Controller National Instruments FW-7344 Hardware User Manual. 1) When I am stationary and command a Halt, there is a resulting jerk movement, sometimes up to a few 1000 servo steps. I would like to implement the same thing using FP & Softmotion instead of 7344 board as later I would like to implement fuzzy logic control into softmotion. I would like to implement the same thing using FP & Softmotion instead of 7344 board as later I would like to implement fuzzy logic control into softmotion. 5500. Options. Hi, I updated my PCI-7344 + LabView 7. At this point, NI Motion will only operate in LabView 32-bit independant of 32-bit or 64-bit OS. NI-Motion Issue Details I can command my motion controller to move a stepper motor to a target position in Open Loop mode, but when I configure it to run in Closed Loop mode, the motor doesn't appear to complete the move, doesn't move at all,. It is very likely that you will not be able to simulate the FW-7344 controller in MAX, due to these limitations. PCI-7390 Driver. In my VI, I have called the Enable Limits. The "Encoder Index found" led is green. Restart and reinstall the drivers for NI-Motion - this will also add MAX. Applications Engineering Group. T. . I know there is in flexmotion library the : Initialize controller. But. Without seeing the program, it's impossible to tell but execution highlighting and single step mode changes the way the program executes and. I have 7330. I am usi. vi". 08-10-2007 01:26 AM. The 7344 can do a frequency of 40 Hz or 78 Hz (which either. If i have NPN or PNP switch as the input to the limits and home input, will it work? Thank you,When I transferred my PCI-7344 motion controller board to another PC, it is recognized "PXI4200"in MAX. 1. 02 seconds. Using MAX to test the. To do so, I would like to write a simple C program to, every specified sampling time T, do the followings: read encoder, calculate output. 08-10-2007 01:26 AM. Options. At times we have seen commands to one axis result in another axis moving. Additionally it incorporates LabVIEW RT and LabVIEW FPGA programming. Work with our experts to sustain your critical applications. But the MAX couldn't read the current traject. I am using PCI-7344 control card with MID-7654 amplifier driving a three axis dc motor servo system. PXI-7344 PXI/CompactPCI PCI-7344 PCI FW-7344* IEEE-1394 * Windows 2000/Me/98 only. The 7344/7334 controllers are designed for PCI, PXI, and 1394 bus computers. used. g. 1, PCI-7344, Amplifier MID-7654, 4 motor-encoders. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. The 7344 controllers are warranted against defects in materials and workmanship for a period of 1 year from the date of shipment, as evidenced by receipts or other documentation. Fault+. I have tried all the Settings discussed in the Forums and they still don't run. 問題: 我嘗試要重設位置,但是總是不會歸零。 我的位置總是會被重設到零以外的數值,我該如何將它變為零. 7)and NI-DAQ 7. . Thanks, Hello Everyone, The Stepper Motors on My machine don't move on my machine, I have PCI -7344 card connected to UMI 7764 with 68 pin connector. We need to AND this output with one of the DIGITAL OUTPUT PORT of PCI 7344 . jspaarg. controller in the 7344 family and contains information concerning their operation and programming. Periodically the servo system does not work. After this software upgrade, several things changed. Axis 1) In the Axis Configuration tab, set Type to Stepper. On the other hand please take into account that the PID loop is running much faster and in order to align the trajectory generation rate ( = 10 ms in contoured mode) and the PID rate (= up to 62,5 µs) the DSP is calculating interjacent setpoints at the rate of the. Re: problems with a PCI-7344 motion controller. The onboard CPU uses an embedded real-time OS. The pulse should last from 1. I am using LabVIEW 2014 and NI PCI 7344(motion controller). I am using LabVIEW 2014 and NI PCI 7344(motion controller). 12-10-2002 05:13 AM. Lai Wechat:17750010683 Whats app:+86 17750010683The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. I am a Master’s student of International Islamic University Malaysia. There are three cards PCI-7344 with the same behavior. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Cary, NC,. Regards Sudhir Sawant Emai. I am using four amplifiers; three are on linear motors, one on a ball screw. Because of the reason mentionned in the link in my first mail, I doubt that a calibration certificate exists for this card. Thank you for your reply !! I am developing pci-7344`s driver under venturecom`s rtx,now I have found the baseadresses[0] and baseadresses[1] . All of 3 motors require +5V 24mA for the Mike encoder. 40. Bgrain, there is no way to tweak a PCI-7344. ), I configure a sequence (in the sequence tab"Find Reference Settings )that the motor finds my" home switch ". Any help is appreciate. . We facilitated the wiring of inputs to each of these components with NI SCB-68 digital I/O connector block and the UMI-7764 motion interface. National Instruments PXI-7344, 777935-01. An introduction to the National Instruments PCI-7344 Motion ControllerFeatured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID. The fourth axis should also operate in contouring mode. Restart and reinstall the drivers for NI-Motion - this will also add MAX. The 7344/7334 family of controllers includes the following controllers: • PCI-7344 • PXI-7344 • FW-7344 • PCI-7334 The 7344/7334. Feel free to check it out here. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. com FlexMotion Software Installation Install the FlexMotion software before installing a FlexMotion series motion controller for the first time. Reply value associated with the本系统以PCI-7344为基础,通过 NI公司最新的LabVIEW8. The PCI‑7344 also provides contouring capability for complex moves. We have a PCI 7344 motion controller and a UMI 7664 interface. Hello, I'm using MAX to disabling Axis, Axis2, Axis3 of PCI-7344 and UMI7774, I click save and "initilize" in MAX, i get message "OK". If you are upgrading from a previousI am using PCI7344 and UMI7774 to do simple control of a motor to make certain movements. 11-09-2010 03:33 PM. NI 7350 NI 7352, NI 7354, NI 7356, NI 7358. Go to the Axis Configuration option, under the desired axis (e. Using the X-Y Grid Inspection (Template). Cary, NC,. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. The 7334 controllersThe PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. Servo motors expect a pulse every . 1 . Lai Wechat:17750010683 Whats app:+86 17750010683Hello, I am fairly new to LabVIEW and was wondering how to implement incremental rotary encoders into a motion control VI. Use a higher resolution encoder. 4-Axis, Stepper/Servo Motion Controller DeviceNI PCI 7344 motion controller was used for controlling the four motors. sooner or later hardware will be discontinued, OS end of life, LabVIEW version not supported, etc. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. 0 Kudos Message 1 of 7 (4,209 Views) Reply. In general NI's support answers quickly. PCI/PXI/FW Installation Complete the following steps to install your PCI/PXI/FW motion controller: 1. I have verified the connection is working. 3008 to 7. PCI-7390 Driver. 展开 PCI-73xx 树. PXI-7344 PXI/CompactPCI PCI-7344 PCI FW-7344* IEEE-1394 * Windows 2000/Me/98 only. 3. The secret is getting the correct Parker-Compumotor Gemini cable that plugs into the. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. 01-30-2006 10:29 AM. flx with a PCI-7344 motion controller to gather velocity data from 3 axes at 333Hz for about 4 seconds. Hello! I want do control a DC-motor (no stepper motor). Return to Home Page; Toggle navigation; Solutions. The National Instruments PCI-7342 / 7344 also provides contouring capability for complex moves. Does anyone by chance has this card running on WIN10 daqmx? Thanks for Your help. 02 seconds. 12 PCI 7344 MAX -Two-axis Configurations 39 3. flx, but i don't know how to wire it. I am using LabVIEW 2014 and NI PCI 7344(motion controller). Software Changes: All of these settings are at Device and Interfaces >> NI-Motion Devices >> Default 73xx Configuration >> Axis x >> Axis Configuration >> Stepper Settings . 1 (NIMotion7. Is it possible to realize such a sample rate with breakpoints and an onboard program like: "Modulus Breakpoint (on-board re-enable). This makes the motor really hot. 10-02-2007 06:58 AM. Starting on page 5-9. Re: Position Control of compumotor linear servo table and GV-U6E with PCI-7344. 1. Aerospace, Defense. fr (Christelle Basset) wrote in <3A407125. 25 ms corresponding to 0 degrees, 1. Options. Restart and uninstall NI-Motion and Measurement & Automation Explorer (MAX) using the Add/Remove Programs Applet in the Control Panel. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. I triggered the Measures over RTSI0 with 50Hz(for a. I would also appreciate one for the Video Capture Board PCI-1409. actually the program has. PCI-7344 Servo Products from NATIONAL INSTRUMENTS 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, MOTION. 0) hangs. 8 degree pitch (200 steps per rev). This works fine while no other process on the PC is running. 1) connected to a MID-7604 drive to control three IDC P21T stepper motors. This warranty includes parts and. I have seen a few other places where people have asked to do this but have found other solutions. I continue to get more and more modal errors from the board. 打开测量与自动化浏览器 (MAX) 导航到您的 NI Motion 设备. 3. However, simulating the PCI-7344 will allow you to set up a program to work with a 4-axis motion controller and look into. 00 +$12. The onboard CPU uses an embedded real-time OS. I encountered problems controlling the motor with MAX using a digital signal. When i am using PCI Flex-6C,Finding home functions does not work as the PCI 7344 do, The controller stops axis 1 and axis 2 during the finding home sequences when the axis 3 encountered home switch first. The 7344 family of controllers includes the following controllers: • PCI-7344 • PXI-7344 • FW-7344 The 7344 controllers are high-performance controllers for PCI, PXI. DESCRIPTION Send commands to the PCI device. It includes two processors and a real-time on-board system, and has multi axis insertion function. Now their is a connector on the Motion control card for Digital I/O. A NI PCI-6527 48-bit digital I/O board that resides in another PCI slot inside the PCWhen I transferred my PCI-7344 motion controller board to another PC, it is recognized "PXI4200"in MAX. 3003 DSP from 7. I´m develop an automated platform by means of stepper motors using the PCI 7344 board and the MID-7604. Knight of NI. PCI-7344 PXI-7344 PCI-7352 PXI-7352 PCI-7354 PXI-7354 PCI-7356. Running the motor is not a problem but when it has stopped (there is no load) the servo system still puts out a lot of voltage (+-48V) all the time. 2. Due to a large instal. 1. But the MAX couldn't read the current traject. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or. In the Stepper Settings tab (near the bottom of the screen), select your Stepper Steps Per Revolution, Stepper Loop Mode, Stepper Polarity, Stepper Output Mode, and Pull-in Tries. If it's possible to update your application to LabVIEW 2015+, my company has a replacement solution for PCI-7344. 6 on a separate desktop system with a PCI-7344 motion controller and a PCI-6221 DAQ card. You can select certain frequencies for the PWM which correspond to the divided down 10. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. sooner or later hardware will be discontinued, OS end of life, LabVIEW version not supported, etc. Trusted Enthusiast. I checked the files that the person shared with me which are NI-Motion configurations. . In the second part, you. NI-VISA. C74B552B@univ-valenciennes. 问题:. PCI-7344 Controller module PCI-7344 Controller module Module Clips Drive controller servo motor Contact: Mr. Environment: MAX 3. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. 10-27-2001 03:20 PM. I connect the pins of the control connector of the UMI-7774 (Axis 1) as i describe in the image i attach. 00 shippingi read the ni-motion manual,pci-7344 and umi7774 manual and also the articles about configuring the Position Command mode. In our normal system, we use 16 or 12 bit S/. This was a problem at first, because the amplifier is intended for differential outputs, while my encoders have single. Order international: +1 609. -While controlling the motors in the "Interactive control" tab, the position. Each axis uses 2 Synchro's (1:1 & 36:1 for Course & Fine 90V / 60Hz) for feedback. If I set the motor's. am rules/80-net-setup-link. Previous message: [systemd-commits] src/core Next message: [systemd-commits] 2 commits - Makefile. g. 8. 8. 6. 2 version but I can't be initialize the motion card in MAXDiscontinued NI motion products (PCI/PXI-7334) Affected model numbers include: PCI-7332; PCI-7334; PCI-7342; PCI-7344; PCI-7352; PCI-7354; PCI-7356; PCI-7358Issue Details I have a PCI-7344 with a UMI-7774 and a Yaskawa Servo Motor and Driver. 1, FLEX MOTION 5. If I set the blend factor to 0 or larger values, the sharp corners reserve, but it seems that we h. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. The PCI-7344 is a motion control board that requires the NI-Motion driver software. I am using a PCI-7344 motion controller to control a slide and motor system. This drive is part of an adjustment mechanism which should remain in a stable. PCI-7342 National Instruments PCI-7342 2-Axis Stepper/Servo Controller Card from National Instruments | Buy Today from Artisan. The first two axis (#1 and #2) both work fine. The 10 ms timing for contoured move is the fastest that you can get out of the board. I have 3 ORIEL motors (Model: 18277, 18215) to drive an x-y-z station. We have just recently switched to a new hardware revision and now all boards don't show up with their specific names but with the name of the board family: Board Family Specific Boards. My pr. The cards do not work on a Computer with differen Hardware, nor when the operating system is Windows XP. At the bottom of the screen you should see 4 tabs- General, Firmware, Onboard Memory Manager, and Status. Product Support, I have recently been using a FW-7344 motion controller to drive an experiment. 4>—The 7344/7334 controller includes an eight channel multiplexed, 12-bit ADC capable of measuring ±10 V, ±5 V, 0–10 V, and 0–5 V inputs. 1 Release Notes 4 ni. The program for our instrument is written with Labview 6 and we cannot afford to rewrite it. PCI-7344. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Why would the Blend Complete bit get set rather than. Installing/reinstalling LV or CVI doesn't necessarily install NI-Motion. Mark as New; Bookmark. いつもお世話になっております。 現在,MAX上でモータのチューニングを行っているのですが,以下の4点について教えてください。 (motionボードはPCI-7344,UMIはUMI-7764を用いています) 1,Axis ConfigurationでTypeをServoとした場合に, どのような信号でモータの回転方向(正回転,逆回転)および速度. How do I do that? Hopefully, there is also a way for me to h. Motion Control Module This article will show you how to test motor functionality. Please refer to the contouring examples shipping with LabVIEW. Allen C. the PCI-7344 can control up to four axes. • PCI-7344 • PXI-7344 • FW-7344 • PCI-7334. Along with this, I want to record motion/motor position data into the same file, whenever I give a move (sinusoidal) command. i found. Hardware Using the existing Rhino Robotics Ltd. We used thirty-five digital I/Os for a variety of purposes, including safety interlocks, proximity switches, and optical sensors. The PCI‑7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. Indeed, when we use a newer PCI7344 card, we have driver / firmware compatibility issues. The 7334 controllersHello, We are planning to build a tie rod fatigue test system with Labview and NI PCI-7344 4-Axis Motion Control Board. My requirement is 1 Khz samples . [posted and mailed] christelle. So, am I missing something ?, All the motors are 3rd Party. I'm testing angle sensors whose voltage output is proportional to (you've guessed it. The Motion Controller Interactive Environment helps you test and debug your system using your current initialization settings. 0 Kudos Message 1 of 4 (2,952 Views) Reply. (NI). The 7344 uses a 10. I encountered problems controlling the motor with MAX using a digital signal. Refer to the Glossary section of this manual for definitions of selected related terms. PCI-7344 cua NI Corp se tch hp hai bo ieu khien servo va step motor. What does mean "Trigger Input occurred" and what kind of misconfiguration can cause it? Tanks. It's very dangerous,my compents are allways hit. The FW-7344 is only compatible with LabVIEW versions earlier than LabVIEW 8. 579 views 3 years ago. Any combination of 0 to 4 open loop or closed loop stepper motors and 0 to 4 servo motors (always closed loop) is allowed. The PCI‑7344 also provides contouring capability for complex moves. Hi, I am Xiaofei in the Univerisity of Michigan. We are using 4 axis of the PCI-7344 in open loop stepper mode. We have two linear servohydraulic actuators for applying linear force to tie rod and a servo motor for steering wheel movement. 4-Axis, Stepper/Servo Motion Controller DeviceI'm using onboard (PCI-7344) Labview programming Wait On High Speed Capture (Wait On Condition. 配置您的步进器设置. また、NIのホームパージから. It is connected to a UMI-7764 breakout box. Order toll free: 800. org Mon Sep 8 22:44:35 PDT 2014. Hi, I am using a PCI-7344 with a UMI-7764 to try and control 3 linear actuators and 1 semi-rotary actuator, each of these actuators takes a 0-10v dc voltage and has a feedback signal of 0-10v dc, both input and output being proportional to linear/angular displacement. 我使用的硬件是PCI-7344,UMI-7764,Sanyo 伺服驱动器和伺服马达一套 运动控制卡的驱动是NI-Motion7. I'm programming a 3-axis piezo stage to do fast scanning (128x128 points in ~ 5 seconds) with a PCI-7344. Lực cắt tham chiếu CNC FANUC Máy tính 2 + Phần mềm hiển thi (DASYLab)+ Điều khiển thích nghi Q trình phay Lượng chạy dao Card điều khiển Flexmotion PCI - 7344 Máy tính 1 + CNC Controller Card PCL -812PG Điều chỉnh lượng chạy dao Luợng chạy dao Lực kế Hình 1. PCI-7344 PXI-7344 PCI-7352 PXI-7352 PCI-7354 PXI-7354 PCI-7356. My application requires 6 axis and hence I want to use two PCI 7344 motion controllers. The manual of PCI-7344 mentions about by setting blend factor to -1 to get smooth motion path. I have been using a PCI-7344 (driven by NI Motion 5. The Payment Card Industry (PCI) Data Security Standards (DSS) is a global information security standard designed to prevent fraud through increased control of. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. This warranty includes parts and labor. また、NIのホームパージから. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. When I command an axis to move, there. . Unfortunately the output pulse has a length of about 20 ms and so I have to decrease the speed of my stage rapidly (otherwise the. 5,控制方式采用的是位置控制模式. Servo motors expect a pulse every . The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. 75 ms. The indexes are offset from each other. controller in the 7344 family and contains information concerning their operation and programming. My email id is sy. . Regards, Shut down the system and physically remove the PCI-7344 from the system (important to remove resource locks). ) Issue: W. And see the result. While this is happening, I need to change the velocity of one of the motors. Tie rod must be vibrated by linear servo hydraulic. When I set it up with the Ni-7344 the drive is ready (green led on drive flashes). 0 and NI-Motion 7. We used thirty-five digital I/Os for a variety of purposes, including safety interlocks, proximity switches, and optical sensors. 0. 6: Cấu trúc của máy phay CNC. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. The Stepper Motors on My machine don't move on my machine, I have PCI -7344 card connected to UMI 7764 with 68 pin connector. . We have successfully done several projects using the Parker-Compumotor Gemini GV servo drive and the NI-7344 and the NI UMI-7764 breakout box. I have PCI-7344 and PCI-6023E and I want to synchronize them so that my DAQ card will start and stop the acquisition definitely when the motion start and stop. The fact is ,as most say,the driver is not suitable under non-windows systems. I am already using one. Hello, I have been using a PCI-7344 motion controller along with LabView to control a 3-dimensional motor/slider system. In the second part, you program for the PCI-7344 controller, which adds several advanced features including the ability to run onboard programs. i finally start to understand the setting after i read the PCI7390 which is position-comannd controller. Motion Control 7344 Hardware User Manual 7344 Hardware User Manual July 1999 Edition Part Number 322504A-01. The Hardware limits work as expected. The reason for the 64-bit operation is a 3rd party function generator card that requires 64-bit LabView to work in conjunction with the 64-bit drivers. . Thanks. いつもお世話になっております。 daqの外部クロック読み込みについて質問があります。 現在、pci-7344およびpci-7764を用いて、サーボアンプからのエンコーダ信号を読み取り、この信号を外部クロックとして、pci-6221に入力する電圧を読み取りたいと思っています。Im using a UMI-7774 and a PCI-7344 motion controller with a Compax C3 servo drive. g. Hi all, I'm using the output pins of the 7344 - board. Conventions National Instruments PCI-7344 Motion Controller Device. To guarantee the delay-free commands flow we use the programmable FPGA device present on the NI-Motion PCI-7344 stage controller board. PCI-7342 2 32 12 PCI-7344 4 32 12 PXI-7342 2 32 12 PXI-7344 4 32 12. The strangest part of all this is that I rarely saw modal errors and now they are becomming common and the VIs have not changed. If you are installing a PCI or PXI controller, install the controller in an available slot in your computer. In the Stepper Settings tab (near the bottom of the screen), select your Stepper Steps Per Revolution, Stepper Loop Mode, Stepper Polarity, Stepper Output Mode, and Pull-in Tries. Right now I have completed the wiring of feedback from motor encoder and managed to see encoder readings in MAX. You won't be able to achieve these types of signals with a 7344 motion control board. Go to the Axis Configuration option, under the desired axis (e. Re: problems with a PCI-7344 motion controller. Downloadable Technical Manuals and Datasheets. I am adding a fourth, separate axis of motion to the system. Save on shipping. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100PCI-7344, 4-Axis, Motion Controller National Instruments PCI-7344 Motion Controller DeviceFeatured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID loop update rate, the National Inst. Send. If yes, then how to configure the other one, so. So I wonder if there is driver u. 2. Its very easy to configure using MAX and also easily programmable using the simple to understand VIs provided by NI. 4-Axis, Stepper/Servo Motion Controller Device4-Axis, Stepper/Servo PXI Motion Controller Module —The PXI‑7344 is recommended for both simple and complex motion applications.